Powerware®FERRUPSFE/QFE UPSInstallation Guide500 VA–18kVA,50and60Hz
Safety Warnings4Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCAUTION: Batteries can present a risk of elec
Safety Warnings5Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comADVARSEL: Batterier kan udgøre en fare for el
Safety Warnings6Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comOPGELET: Batterijen kunnen gevaar voor elektr
Safety Warnings7Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comVARO: Akusto saattaa aiheuttaa sähköiskun tai
Safety Warnings8Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comATTENTION!: Les batteries peuvent présenter u
Safety Warnings9Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comVORSICHT!: Batterien können aufgrund des hohe
Safety Warnings10Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com::::Avvisi di sicurezzaIMPORTANTI ISTRUZIONI
Safety Warnings11Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com: Per ridurre il rischio di incendio o di sc
Safety Warnings12Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com: Alt utstyr som er forbundet med utgangen a
Safety Warnings13Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comPERIGO: As baterias podem apresentar o risco
Safety Warnings14Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com: Для обеспечения соблюдения требований межд
Safety Warnings15Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com: Para reducir el riesgo de incendio o de ch
Safety Warnings16Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com: Minska risken för brand eller elektriska s
17Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 3SETUPThis chapter explains the requirements for se
Setup18Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comTable 2. FERRUPS FE/QFE 4.3–18 kVA DimensionsDimension
Setup19Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comDDABBPE-01 BPE-02, 04, and 05CEABCEFigure 3. Bypass Sw
Setup20Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comJIIGGHHFigure 4. Installation and Service ClearancesLo
Setup21Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comStorage and Operating EnvironmentStorage Temperature:
Setup22Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com
23Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 4ELECTRICAL INSTALLATIONNOTE If you have a plug-rec
Powerware®FERRUPSFE/QFE UPSInstallation Guide500 VA–18kVA,50and60Hzwww.powerware.com
Electrical Installation24Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comBypass SwitchesBypass switches are a
Electrical Installation25Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comTable 7 and Table 8 show the bypass
Electrical Installation26Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comConnect to (DC)External BatteriesBui
Electrical Installation27Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comFigure 6 shows a UPS with a separate
Electrical Installation28Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com
29Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 5EXTERNAL BYPASS SWITCH INSTALLATIONWARNINGOnly qua
External Bypass Switch Installation30Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comWiring DiagramBypass Swi
External Bypass Switch Installation31Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com2. Review the installati
External Bypass Switch Installation32Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCAUTIONTo prevent electr
External Bypass Switch Installation33Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com8. Find the terminal str
Class A EMC StatementsFCC Part 15NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant topart
External Bypass Switch Installation34Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com10. If your UPS does not
External Bypass Switch Installation35Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comNOTE 8 External UPS batt
External Bypass Switch Installation36Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comQFE: 50 Hz 120 Vac Input
External Bypass Switch Installation37Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 208 Vac or 240 Vac
External Bypass Switch Installation38Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 208 or 480 Source/
External Bypass Switch Installation39Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com50 Hz 220, 230, or 240 V
External Bypass Switch Installation40Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 120 Vac Input - 12
External Bypass Switch Installation41Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 208 Vac or 240 Vac
External Bypass Switch Installation42Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 208 or 480 Source/
External Bypass Switch Installation43Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comQFE: 50 Hz 220, 230, or
iPowerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comTABLE OF CONTENTS1 Introduction 1...
External Bypass Switch Installation44Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com
45Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 6INTERNAL BYPASS SWITCH INSTALLATIONWARNINGOnly qua
Internal Bypass Switch Installation46Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com2. Review the installati
Internal Bypass Switch Installation47Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCAUTIONTo prevent electr
Internal Bypass Switch Installation48Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comInstallation Wiring Diag
Internal Bypass Switch Installation49Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comNOTE 10 The load fuse or
Internal Bypass Switch Installation50Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 208 Vac or 240 Vac
Internal Bypass Switch Installation51Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com60 Hz 208 or 480 Source/
Internal Bypass Switch Installation52Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comQFE: 50 Hz 220, 230, or
53Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 7BATTERY CABINET INSTALLATIONNOTE If you have an op
Table of ContentsiiPowerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com
Battery Cabinet Installation54Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com: Align the cables on the batte
Battery Cabinet Installation55Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comTable 27. Nominal DC Battery Vo
Battery Cabinet Installation56Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comInstalling and Connecting the B
Battery Cabinet Installation57Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com4. The battery cabinet ground (
Battery Cabinet Installation58Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com5. Arrange the batteries in the
Battery Cabinet Installation59Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comNOTE If you have an external DC
Battery Cabinet Installation60Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comSquare: Torque to17 in lb or 1.
Battery Cabinet Installation61Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com:If your battery cabinet has a
Battery Cabinet Installation62Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comNOTE If you have an external DC
Battery Cabinet Installation63Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comReplacing the BatteriesCAUTIONO
1Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 1INTRODUCTIONThe Powerware FERRUPS uninterruptible p
Battery Cabinet Installation64Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com3. Handle used batteries with c
65Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 8PHASE CHECKAfter all hardwired connections are com
Phase Check66Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com10–18 kVA: If you have an external battery cabin
Phase Check67Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comExternal Bypass SwitchBPE-01AC from UPSOutputMea
Phase Check68Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com10. Measure the AC voltage between the following
Phase Check69Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com16. Turn off the DC switch, if applicable, accor
Phase Check70Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com
Introduction2Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.com:If you purchased an external battery cabinet, s
3Powerware®FERRUPS FE/QFE UPS (500 VA–18 kVA) Installation Guide : Rev A www.powerware.comCHAPTER 2SAFETY WARNINGSRead the following precautions befor