Model ST-2400S
Horsepower Computer System
User Manual
In the USA:
Star Test Dynamometer, Inc.
712 Thistlewood Court
Normal, IL 61761
Phone: (309) 826-1484
In Mexico, Central & South America:
Negociaciones Fuentes S.A. DE CV
Av. La Luz 4549 Col. Cortijo del Rio
Monterey, N.L. Mexico 64890
Phone: 81.8349.1416
Manufacturered by:
Ries Labs, Inc.
2275 Raven Road
Farina, IL 62838
Phone: (618) 238-1400
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1

Model ST-2400S Horsepower Computer System User Manual In the USA: Star Test Dynamometer, Inc. 712 Thistlewood Court Normal, IL 61761 Phone: (309) 8

Page 2 - Table of Contents

recording can be controlled from the 2400S horsepower computer and / or using the personal computer’s keyboard or mouse. Recorded data can be printed

Page 3 - Installation:

2.) The instrument has been moved (re-installed) from one dynamometer to another. 3.) The load cell of the dynamometer has been replaced, overloaded

Page 4 - Operation:

the torque arm of the dynamometer to insure that there is no force being applied to the load cell (which would result in an inaccurate zero calibratio

Page 5 - Computer Function Switch:

positive and negative torque to the unit) and verify that the torque reading returns closely to the same value. A failure here indicates a likely prob

Page 6 - 10,000 3750 2856

dynamometer. The calibration torque produced is equal to the sum of the torque produced by the Torque Test Bar itself plus the torque produced by the

Page 7

In Case of Difficulty: The following is a troubleshooting guide that will help you to resolve any problems that may arise. The Model 2400S Horsepow

Page 8

The following table is useful for you to determine that cause of any problems that you might be able to fix yourself. Problem Possible causes and r

Page 9

and the RPM sensor gear. Make sure that they are not loose and that the runout of the RPM gear is not excessive. Check the RPM sensor connector to be

Page 10

Table of Contents Description ---------------------------------------------------------------- 3 Installation -------------------------------------

Page 11 - Calibration Procedure:

Description: The function of the Model 2400S Horsepower Computer is to provide the operator with a continuous digital readout of the RPM, TORQUE, POW

Page 12 - Calibration Procedure Notes:

Power Supply: The Model 2400S horsepower computer is normally operated from 110 to 125 VAC (60 Hz) using the outlet mounted power supply that is sup

Page 13 - Torque Calibration Notes:

values are computed and displayed. This process is repeated continuously while the unit is in operation. Computer Function Switch: The computer fun

Page 14

10,000 3750 2856 CHECK readings using Ft.-Lbs. & Horsepower 6

Page 15

Load Cell Rating (Ft.-Lbs.) Torque (N-M) Power (KW) 100 (135.5 N-M) 50.84 21.30 200 (271 N-M) 101.6 42.60 500 (677.5 N-M) 254.2 106.5 1,000 (

Page 16

The torque set switch is used to set the torque reference which is used to compute the % Torque Rise reading. To set the torque reference, proceed as

Page 17

When the horsepower computer is used with a companion personal computer, a standard (9 pin) RS-232-C extension cable is used to connect the two compu

Comments to this Manuals